mirror of
https://github.com/AletheiaVox/signal_bridge_remote.git
synced 2026-10-07 03:18:17 +08:00
docs: OAuth connector setup, governor config, feature_index; add changelog
- claude.ai connector section now documents the OAuth login flow as the primary path, with the authless single-user fallback as Option C. - Project structure, requirements, and .env docs updated for the OAuth + governor modules; pointer to .env.example for the governor knobs. - Tools table covers the extended output types, the escalate hold contract, and feature_index for multi-motor devices. - Safety Features section documents the governor. - CHANGELOG.md records v1.1 and the v1.0 baseline. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
41
README.md
41
README.md
@@ -90,15 +90,19 @@ On your local machine, create the project directory and prepare files. The proje
|
||||
signal-bridge-remote/
|
||||
├── Dockerfile
|
||||
├── docker-compose.yml
|
||||
├── .env
|
||||
├── .env (copy .env.example and fill in)
|
||||
├── requirements-server.txt
|
||||
├── requirements-phone.txt
|
||||
├── server/
|
||||
│ ├── __init__.py
|
||||
│ ├── app.py
|
||||
│ ├── auth.py
|
||||
│ ├── config.py
|
||||
│ ├── governor.py
|
||||
│ ├── models.py
|
||||
│ ├── mcp_tools.py
|
||||
│ ├── oauth.py
|
||||
│ ├── oauth_routes.py
|
||||
│ ├── relay_hub.py
|
||||
│ ├── safety.py
|
||||
│ └── session_registry.py
|
||||
@@ -147,6 +151,7 @@ websockets>=12.0
|
||||
bcrypt>=4.1.0
|
||||
PyJWT>=2.8.0
|
||||
python-dotenv>=1.0.0
|
||||
python-multipart>=0.0.9
|
||||
```
|
||||
|
||||
**.env:**
|
||||
@@ -158,12 +163,20 @@ SB_HOST=0.0.0.0
|
||||
SB_PORT=8420
|
||||
SB_REGISTRATION_OPEN=true
|
||||
SB_TOKEN_EXPIRY_HOURS=720
|
||||
# true = every MCP request must be authenticated (multi-user servers).
|
||||
# false = single-user convenience: unauthenticated MCP requests go to the
|
||||
# sole connected phone.
|
||||
SB_REQUIRE_MCP_AUTH=false
|
||||
SB_HEARTBEAT_INTERVAL=2.0
|
||||
SB_HEARTBEAT_TIMEOUT=6.0
|
||||
SB_BAN_THRESHOLD=20
|
||||
SB_BAN_DURATION_MINUTES=30
|
||||
```
|
||||
|
||||
See [.env.example](.env.example) for the full list, including the safety
|
||||
governor's tuning knobs (`SB_GOVERNOR_*` — heat/cooldown rates for the
|
||||
session intensity limiter).
|
||||
|
||||
Upload to your VPS:
|
||||
|
||||
```bash
|
||||
@@ -290,17 +303,21 @@ Add this MCP server config:
|
||||
|
||||
Restart Claude Desktop. You should see Signal Bridge in your available tools.
|
||||
|
||||
### Option B: claude.ai Custom Connector (authless)
|
||||
### Option B: claude.ai Custom Connector (OAuth)
|
||||
|
||||
Claude.ai supports custom MCP connectors without authentication, using a fallback mechanism: when only one phone is connected, all MCP requests are routed to that phone automatically.
|
||||
The server implements the full OAuth 2.0 flow that claude.ai custom connectors expect (discovery metadata, dynamic client registration, authorize + token endpoints). Each user logs in with their own Signal Bridge account, so this works properly on multi-user servers.
|
||||
|
||||
1. Go to claude.ai Settings (or click the connector icon in the chat)
|
||||
2. Choose "Add custom connector" (or "Add MCP server")
|
||||
3. Enter your server URL: `https://signal-bridge.duckdns.org/mcp`
|
||||
4. Leave authentication as "None"
|
||||
5. Save
|
||||
4. Save — claude.ai will open your server's login page
|
||||
5. Sign in with the username and password you registered in step 1.4
|
||||
|
||||
**Important**: The authless fallback only works when exactly one phone/relay client is connected to the server. If no phones are connected, claude.ai will show a connection error. Start your relay client first, then connect from claude.ai.
|
||||
### Option C: claude.ai without login (single-user fallback)
|
||||
|
||||
If you skip the OAuth login, the server falls back to routing unauthenticated MCP requests to the sole connected phone — convenient for a private single-user server.
|
||||
|
||||
**Important**: The authless fallback only works when exactly one phone/relay client is connected to the server (and is disabled entirely when `SB_REQUIRE_MCP_AUTH=true`). If no phones are connected, claude.ai will show a connection error. Start your relay client first, then connect from claude.ai.
|
||||
|
||||
---
|
||||
|
||||
@@ -466,18 +483,19 @@ Once connected, Claude has access to these tools:
|
||||
|
||||
| Tool | Description |
|
||||
|------|-------------|
|
||||
| `list_devices` | Show connected devices and their capabilities |
|
||||
| `list_devices` | Show connected devices, their output channels, and governor state |
|
||||
| `scan_devices` | Rescan for new or reconnected Bluetooth devices |
|
||||
| `vibrate` | Send vibration (intensity 0.0–1.0, optional duration in seconds) |
|
||||
| `rotate` | Rotation or sonic output (device-dependent) |
|
||||
| `oscillate` | Thrusting/oscillation output |
|
||||
| `rotate` | Rotational/high-frequency actuator output (device-dependent) |
|
||||
| `oscillate` | Linear reciprocating output |
|
||||
| `constrict` / `temperature` / `led` / `position` / `spray` | Extended outputs for devices that support them |
|
||||
| `pulse` | Rhythmic on/off pattern |
|
||||
| `wave` | Smooth sine-wave intensity modulation |
|
||||
| `escalate` | Gradual ramp from 0 to peak, with optional hold |
|
||||
| `escalate` | Gradual ramp to peak; `hold_seconds` > 0 auto-stops after holding, 0 holds until stopped |
|
||||
| `stop` | Immediately stop all output (also cancels patterns) |
|
||||
| `read_battery` | Read device battery level |
|
||||
|
||||
All output tools accept `device` (name or "all"), `intensity` (0.0–1.0), and `duration` (seconds, 0 = until stopped). Pattern tools also accept `output_type` to modulate rotation or oscillation instead of vibration.
|
||||
All output tools accept `device` (name or "all"), `intensity` (0.0–1.0), and `duration` (seconds, 0 = until stopped). Pattern tools also accept `output_type` to modulate rotation or oscillation instead of vibration. Multi-motor devices (e.g. Lovense Edge, Dolce) additionally take `feature_index` to drive one motor independently — omit it to drive all matching motors together.
|
||||
|
||||
---
|
||||
|
||||
@@ -486,6 +504,7 @@ All output tools accept `device` (name or "all"), `intensity` (0.0–1.0), and `
|
||||
Signal Bridge has several safety mechanisms built in:
|
||||
|
||||
- **Dead Man's Switch**: The server pings the relay client every 2 seconds. If 3 pings go unanswered (6 seconds), the server sends an emergency stop to all devices and disconnects the session. Your devices will never be left running if the connection drops.
|
||||
- **Safety Governor**: A server-side heat model (intensity × time) that forces a cooldown when a session runs too hot for too long. Tunable server-wide via `SB_GOVERNOR_*` env vars and per-user via `GET`/`POST /safety/config`; current heat is shown in `list_devices` and can be disabled per user.
|
||||
- **Auto-stop on Duration**: Commands with a `duration` parameter automatically stop after the specified time.
|
||||
- **Fallback Stop**: If a stop command references a device name that doesn't exist, ALL devices are stopped as a safety fallback.
|
||||
- **Rate Limiting**: Prevents command flooding (120 commands/minute default).
|
||||
|
||||
Reference in New Issue
Block a user